Advanced design
MCU control, 304SUS liner, easy to clean, easy operation
Uniform internal ventilation, 25mm observe hole on left side
Performance guaranteed
Two sets compressors automatic switch guarantee long period continuous operation
No need for defrost in continuous running
Quality guaranteed
Imported products for Temperature humidity controller, compressor, circulating fan, guarantee stable performance
Safety function
Independent temperature limit alarm system, sound and light alarm prompt
Imported humidity sensor which can run under high temperature
UV sterilization system(optional)
The UV sterilization lamp located on the back wall of cabinet, which can disinfect the inside cabinet regularly;
Illuminance automatic monitoring and control(optional)
Optical sensor for illuminance monitoring and it’s stepless regulation, which can reduce the damping and test error due to lamp error;
Data record and error diagnose
When error occurred, screen will display error information; can connect with printer or RS485 port
Programmable touch screen controller(optional)
Large screen touch screen
English operation menu, real time running curve display
100units 1000 sectors 999steps circulation steps capacity, each sector max set time is 99hrs 59mins
Controller has screen lockout function
PID automatic calculation function can automatically correct the varying condition of temperature and humidity
RS232 or RS485 port
Technical Specifications
| Item | Pharmaceutical stability test chamber | Comprehensive Pharmaceutical stability test chamber | Pharmaceutical strong illuminance stability test chamber | |
| Model | YPW-80SD YPW -150SD YPW -250SD | YPW -80SDP YPW -150SDP YPW -250SDP | YPW -150GSD YPW -150GSP YPW -250GSD YPW -250GSP | YPW -150GP YPW -250GP YPW -400GP |
| Pharmaceutical long term stability test storage condition | Temperature | +25℃±2℃ | ||
| Humidity | 60±5%RH | |||
| Period | 12months | |||
| Accelerated stability test storage condition | Temperature | +40℃±2℃ | ||
| Humidity | 75±5%RH | |||
| Time | 6months | |||
| Illuminance strength | 4500±500LX | |||
| Temperature range | 0~65℃ | Without illuminance 0~65℃; with illuminance 10~65℃ | ||
| Temperature fluctuation/uniformity | ±0.5℃/±2℃ | |||
| Humidity range/ Deviation | 40~95%RH/ ±3%RH | No | ||
| Illuminance / Deviation | No | 0~6000LX adjustable≤±500LX(stepless dimming) | ||
| Timing range | Each section 1~99hrs | Each section 1~99hrs | Each section 1~99hrs | Each section 1~99hrs |
| Temperature humidity regulation mode | Equivalent temperature humidity regulation mode | Equivalent humidity regulation mode | ||
| Refrigerating system / refrigerating mode | Two sets original imported full sealed compressor automatic switch (LHH-80SD/80SDP only one set) | |||
| Controller | Programmable LCD controller | Programmable Touch screen controller | GSD: programmable LCD controller GSP: programmable touch screen controller | Programmable touch screen controller |
| Sensor | Pt100 | Pt100 | ||
| Working temperature | RT+5~30℃ | |||
| Power supply | AC 220V±10% | 50HZ | ||
| Power supply | 1900W/2200W/2400W | 2300W/2600W | 1500W/1800W/3200W | |
| Volume | 80L 150L 250L | 80L 150L 250L | 150L 250L | 150L 250L 400L |
| Liner size(mm) W×D×H | 400×400×500 550×405×670 600×500×830 | 400×400×500 550×405×670 600×500×830 | 550×405×670 600×500×830 | 550×405×670 600×500×830 700×550×1140 |
| overall size(mm) W×D×H | 550×790×1080 690×805×1530 740×890×1680 | 550×790×1080 690×805×1530 740×890×1680 | 690×805×1530 740×890×1680 | 690×805×1530 740×890×1680 950×850×1850 |
| Support | 2/3/3pcs | 2/3/3pcs | 3/3pcs | 3/3/4pcs |
| Printer | Equipped | |||
| Safety device | Overheat protection, fan overheat protection, over temperature protection, compressor over pressure protection, overload protection, water shortage protection | |||